Ethernet Thermo Hygro-barometer, Modbus TCP, REST, MQTT, OPC UA

Ethernet Thermo Hygro-barometer, Modbus TCP, REST, MQTT, OPC UA


Industrial thermometer with hygrometer and barometer, stores data in internal memory or provides it over Ethernet network to parent applications via OPC UA/DA, MQTT, REST, Modbus TCP, etc. JavaScript support for browser data display, alarm system, W&T Cloud support. DIN rail mounting. Possibility to certify measurements for 1 year. More

Manufacturer: W&T Code: 57713

438 EUR excl. VAT (529,98 EUR incl. VAT)
Recycling fee 0,04 EUR v cene.
In stock
pcs
(0 pcs in stock)
Buy more for 230 EUR and get free delivery!
0 EUR230 EUR

Industrial thermometer with hygrometer and barometer, stores data in internal memory or provides it over Ethernet network to parent applications via OPC UA/DA, MQTT, REST, Modbus TCP, etc. JavaScript support for browser data display, alarm system, W&T Cloud support. DIN rail mounting. Possibility to certify measurements for 1 year. More

Manufacturer: W&T Code: 57713

Sensor:

  • Temperature sensor:
    • Measure range: -40°C...85°C
  • Relative humidity sensor:
    • Measuring range 0..100% RH, permissible ambient: 0..95% (non-condensing)
  • Air pressure sensor:
    • Measuring range 10-1100 hPa

Connectivity:

  • Intuitive Web interface for simpler configuration
  • Monitor temperatures and trends from a browser
  • Alarm and reporting function:
    • E-mail for alarm or reporting functions
    • SNMP polling / alarm traps
    • Configure up to 12 alarm messages
  • Dynamic integration into other Web sites:
    • Direct access to current measurement values, e.g. JavaScript (AJAX).
  • Current industry 4.0 protocols:
    • OPC UA, REST and MQTT support
  • Additional software interfaces for incorporating into your systems/databases:
    • SNMPv1, SNMPv2c, SNMPv3
    • Modbus-TCP
    • OPC UA, OPC DA
    • Syslog
    • Sensobase (database integration via ODBC)
    • TCP and UDP sockets, client and server
    • FTP (data logging)
  • Possible applications:
    • Monitor temperatures in the server room, network cabinet or office
    • Logging of measurements via FTP, Excel file, email attachment and internal memory
    • dew point measurement, climate monitoring
    • Green IT: Monitor efficiency of the server room climate control

Data logger:

  • Internal data logger
    • Memory size: min. 7 weeks, max. 20 years
    • Save frequency: 15, 30 sec, 1, 5, 15, 60 min
  • Document measurement data online in the W&T Cloud and access from anywhere in the world
  • Internal clock
    • Time synchronization via time server calibration
    • Battery-backed device clock

Standards & more

  • optional: ISO factory calibration per DIN EN ISO/IEC 17025
    • with calibration certificate for verified documentation of the measured value deviations
    • Valid for 12 months
  • optional: DAkkS/DKD calibration per DIN EN ISO/IEC 17025
    • with calibration certificate for verified traceability to national standards
    • Valid for 12 months
  • Supply voltage via Power-over-Ethernet (PoE)
    • Phantom power using data pairs
    • Power over unused wire pairs
    • External power supply is an alternative
  • Conforms to standards both in office and industrial environments:
    • High noise resistance per EN 61000-6-2
    • Low noise emission per EN 55032:2015 + A1 Cl. B, EN 61000-3-2 & EN 61000-3-3
  • 5 year guarantee

Connections and displays:

  • Combined sensor:
    • Temperature, relative humidity and air pressure measurement
    • DB9 receptacle
    • Cable length: 2m (can be extended to max. 20m)
  • Network:
    • 10/100BaseT Autosensing/Auto-MDIX
    • RJ45
    • IPv6 on request
  • Galvanic isolation:
    • Network connection min. 1500 V
  • Power supply:
    • Power-over-Ethernet (PoE) or
    • DC 12V .. 48V (+/-10%) or
    • AC 18Veff .. 30Veff (+/-10%)
  • Supply connection:
    • Plug-in screw terminal, 5.08mm spacing
    • Labeled "L+" and "M"
  • Current consumption:
    • PoE Class 1 (0.44 - 3.84W)
    • typ. 62mA @24VDC, 80mA @20VAC,
    • max. 70mA @24VDC, 40mA @48VDC
  • Displays:
    • 1 LED Power
    • 2 LEDs Network Status
    • 4 LEDs Status and Error

Measuring unit:

  • Measuring range:
    • -40°C...85°C, 0..100% rF, 10-1100 hPa
  • Resolution:
    • 1/10 °C, 1/10% rF, 0.1 hPa
  • Display variables:
    • °Celsius, °Fahrenheit, °Kelvin,
      %relative humidity, abs. humidity g/m³, dew point °C,
      barometric pressure mBar, hPa,
      mixing ratio g/kg, enthalpy kJ/kg

  • Measuring error:

    • Temperature:
    • typ. @ 25°C ±0.3°C
    • max. @ -40..85°C ±1.5°C

    • Relative humidity:
    • typ. @ -20..60°C (normal range) ±1.8%rH (10-90%rH)
    • max. @ -20..60°C (normal range) ±4%rH (0-100%rH)
    • temporary @ -40..85°C (max range) +3%rH after 60h of operation
    • outside normal range
    • Long-term stability typ. <0.5%rH / year

    • Atmospheric pressure:
    • typ. @ 25°C ±0.8hPa (750..1100hPa)
    • max. @ 25°C ±2.5hPa (750..1100hPa)
    • max. @ -40..85°C: ±3.5hPa (300..1100hPa)
    • Long-term stability: typ. -1hPa / year
  • Measuring frequency:
    • 4s
  • Storage frequency:
    • 15s, 30s, 1m, 5m, 15m, 60m
  • Memory depth (4MB):
    • min. 7 weeks, max. 20 years

Housing and other data:

  • Housing:
    • Plastic compact housing for top-hat rail mount
    • 105x22x75mm (LxWxH)
  • Enclosure rating:
    • IP20
  • Weight:
    • approx. 200g
  • Ambient temperature:
    • Storage: -40..+70°C
    • Operating: Non-contiguous mounting: 0 .. +60°C
    • contiguous mounting: 0 .. +50°C
  • Permissible relative humidity:
    • 0..95% RH (non-condensing)
  • Scope of delivery:
    • 1x Web-Thermo-Hygrobarometer
    • 1x W&T sensor, 2m (temperature, relative humidity and barometric pressure)
    • 1x Quick Guide