Ethernet Thermo Hygro-barometer, Modbus TCP, REST, MQTT, OPC UA

Ethernet Thermo Hygro-barometer, Modbus TCP, REST, MQTT, OPC UA


W&T

Industrial thermometer with hygrometer and barometer, stores data in internal memory or provides it over Ethernet network to parent applications via OPC UA/DA, MQTT, REST, Modbus TCP, etc. JavaScript support for browser data display, alarm system, W&T Cloud support. DIN rail mounting. Possibility to certify measurements for 1 year. More

Code: 57713

438 EUR excl. VAT (529,98 EUR Incl. VAT)
Recycling fee 0,04 EUR included in the price.
Quantity discount
Units
Discount
Price without VAT

0 - 4
0%
438,00

5 - 9
2%
429,24

10 - 19
5%
416,10

20 and more
9%
398,58

Delivery 3-8 days
pcs
(0 pcs In stock)

Rezervace termínu

Get a quote
W&T

Industrial thermometer with hygrometer and barometer, stores data in internal memory or provides it over Ethernet network to parent applications via OPC UA/DA, MQTT, REST, Modbus TCP, etc. JavaScript support for browser data display, alarm system, W&T Cloud support. DIN rail mounting. Possibility to certify measurements for 1 year. More

Code: 57713

W&T 57713

Temperature, humidity and atmospheric pressure via Ethernet

The W&T 57713 is a networked measurement system with a separate probe for temperature, relative humidity and atmospheric pressure. It offers web-based visualisation, internal data logging and connectivity via OPC UA, MQTT, REST and Modbus TCP.

Do you need to select or order the W&T 57713?
Please send us the required quantity and a description of the wiring configuration. We will check availability and suitable accessories.

Enquire about a product and consultation
-40 to +85 °CSensor temperature range
0–100 % RHRelative humidity measurement range
10–1100 hPaNetwork monitoring environment

Successor model

W&T lists the successor model 57113 for this product. The specifications on this page relate to the original order number 57713. Before selecting a replacement, we will verify the wiring, functions and suitability for the specific application.

Usage

The combined probe measures temperature, relative humidity and atmospheric pressure. The readings are used to monitor the climate and assess conditions in technical areas.

Technical specifications for W&T 57713

Combined sensorMeasurement of temperature, relative humidity and atmospheric pressure
DB9 socket
Cable length: 2 m, can be extended to a maximum of 20 m
Network interface10/100BaseT, auto-detection / Auto-MDIX
RJ45
IPv6 on request
Galvanic isolationNetwork interface section: min. 1500 V
Power supplyPower-over-Ethernet (PoE) or
12–48 V DC (±10 %) or
18–30 V AC, root mean square (±10 %)
Power connectionRemovable screw terminal block, pitch 5.08 mm
Marked ‘L+’ and ‘M’
Current consumptionPoE Class 1 (0.44–3.84 W)
typ. 62 mA at 24 V DC, 80 mA at 20 V AC,
max. 70 mA at 24 V DC, 40 mA at 48 V DC
Signalling1× power LED
2× network status LEDs
4 LEDs – status and faults
Measuring range-40 °C to 85 °C, 0 to 100 % rF, 10–1100 hPa
Resolution1/10 °C, 1/10 % rF, 0.1 hPa
Quantities displayedTemperature: °C, °F, K; relative humidity: % RH; absolute humidity: g/m³; dew point: °C; atmospheric pressure: mbar, hPa; mixing ratio: g/kg; enthalpy: kJ/kg
Measurement errorTemperature:
typ. at 25 °C ±0.3 °C
max. @ -40 to 85 °C ±1.5 °C
Relative humidity:
typ. @ -20 to 60 °C (normal range) ±1.8 % rH (10–90 % rH)
max. at -20 to 60 °C (normal range) ±4 % rH (0–100 % rH)
Temporary humidity deviation: +3 % RH after 60 hours of operation outside the normal temperature range, between -40 and +85 °C
Long-term stability: typically <0.5 % rH/year
Atmospheric pressure:
typ. at 25 °C ±0.8 hPa (750 to 1100 hPa)
max. at 25 °C ±2.5 hPa (750 to 1100 hPa)
max. at -40 to 85 °C: ±3.5 hPa (300 to 1100 hPa)
Long-term stability: typically -1 hPa/year
Measurement period4s
Save interval15 s, 30 s, 1 min, 5 min, 15 min, 60 min
History capacity (4 MB memory)min. 7 weeks, max. 20 years
Housing and mountingCompact plastic housing for DIN rail mounting
105 × 22 × 75 mm (length × width × height)
Degree of protectionIP20
Weightapprox. 200 g
Ambient temperatureStorage: -40 to +70 °C
Operating temperature with spacing between devices: 0 to +60 °C
Operating temperature when installed side by side without spacing: 0 to +50 °C
Permissible relative humidity0 to 95 per cent RH, non-condensing
Contents of the delivery1x web-based thermo-hygrobarometer
1x W&T sensor, 2 m (temperature, relative humidity and barometric pressure)
1× quick start guide

Measured quantities and conditions of use

  • The combined probe measures temperature, relative humidity and atmospheric pressure. The readings are used to monitor the climate and assess conditions in technical areas.
  • The scope of supply includes a combined probe with a 2 m cable. W&T permits the probe connection to be extended to a maximum of 20 m for this model.
  • Values are updated every 4 seconds. The history is stored at separate intervals: 15 or 30 seconds, or 1, 5, 15 or 60 minutes.
  • Up to 12 configurable alerts enable notifications via email or SNMP. The network module and probe have their own operating conditions; the probe’s measurement range is not the same as the module’s operating temperature.
  • A humidity measurement range of 0–100 % RH does not imply that condensation on the electronics is permitted. Permissible operating conditions are specified separately in the technical table.

Commissioning and accessories

Position the probe so that it measures the required area and is not affected by heat from surrounding equipment. Set the IP address, the displayed parameters, the logging interval and the alarm limits. If extending the cable, use suitable cabling and do not exceed a length of 20 m.

Contents of the delivery

  • 1x web-based thermo-hygrobarometer
  • 1x W&T sensor, 2 m (temperature, relative humidity and barometric pressure)
  • 1× quick start guide

Frequently Asked Questions

Can I extend the probe cable?

Yes. This model comes with a 2-metre cable, which can be extended to a maximum of 20 metres. Use cabling that complies with the manufacturer’s wiring specifications.

Does the temperature measurement range also apply to the network module?

No. The measurement range applies to the probe. The module itself has its own specified operating temperature and installation conditions.

What does the stated typical accuracy mean?

Applies under the conditions specified for the particular quantity and range in the table. When assessing these, it is necessary to distinguish between temperature, relative humidity and, where applicable, pressure, as well as long-term stability.

Why buy from FOXON

W&T distributor

We are a distributor of W&T products. We supply new original products with a warranty.

Stock availability and delivery

We check current availability from our own and partner warehouses. Before you order, we confirm the price and possible delivery date for the specific model.

Product selection and technical advice

We help you choose the model, power supply and accessories to suit your connections and communication requirements.

Solution design and configuration

We discuss the connections and application requirements. Where needed, we propose a suitable setup and agree on the scope of assistance with configuration and commissioning.

More than 3,500customers
We supply tomore than 100 countries worldwide
Express delivery?We will check. Contact us now.

Documentation and technical consultancy

Technical data and documentation W&T 57713

Manuals, firmware and tools for this model are also available in the Downloads tab. We can help with product selection and configuration according to your connections and communication requirements.

Do you need to select or order the W&T 57713?
Please send us the required quantity and a description of the wiring configuration. We will check availability and suitable accessories.

Enquire about a product and consultation

Diagrams and illustrations

W&T 57713 – diagram or illustration of the productW&T 57713 – diagram or illustration of the productW&T 57713 – diagram or illustration of the productW&T 57713 – diagram or illustration of the productW&T 57713 – diagram or illustration of the product

Further related links

Technical specifications for W&T 57713

Combined sensorMeasurement of temperature, relative humidity and atmospheric pressure
DB9 socket
Cable length: 2 m, can be extended to a maximum of 20 m
Network interface10/100BaseT, auto-detection / Auto-MDIX
RJ45
IPv6 on request
Galvanic isolationNetwork interface section: min. 1500 V
Power supplyPower-over-Ethernet (PoE) or
12–48 V DC (±10 %) or
18–30 V AC, root mean square (±10 %)
Power connectionRemovable screw terminal block, pitch 5.08 mm
Marked ‘L+’ and ‘M’
Current consumptionPoE Class 1 (0.44–3.84 W)
typ. 62 mA at 24 V DC, 80 mA at 20 V AC,
max. 70 mA at 24 V DC, 40 mA at 48 V DC
Signalling1× power LED
2× network status LEDs
4 LEDs – status and faults
Measuring range-40 °C to 85 °C, 0 to 100 % rF, 10–1100 hPa
Resolution1/10 °C, 1/10 % rF, 0.1 hPa
Quantities displayedTemperature: °C, °F, K; relative humidity: % RH; absolute humidity: g/m³; dew point: °C; atmospheric pressure: mbar, hPa; mixing ratio: g/kg; enthalpy: kJ/kg
Measurement errorTemperature:
typ. at 25 °C ±0.3 °C
max. @ -40 to 85 °C ±1.5 °C
Relative humidity:
typ. @ -20 to 60 °C (normal range) ±1.8 % rH (10–90 % rH)
max. at -20 to 60 °C (normal range) ±4 % rH (0–100 % rH)
Temporary humidity deviation: +3 % RH after 60 hours of operation outside the normal temperature range, between -40 and +85 °C
Long-term stability: typically <0.5 % rH/year
Atmospheric pressure:
typ. at 25 °C ±0.8 hPa (750 to 1100 hPa)
max. at 25 °C ±2.5 hPa (750 to 1100 hPa)
max. at -40 to 85 °C: ±3.5 hPa (300 to 1100 hPa)
Long-term stability: typically -1 hPa/year
Measurement period4s
Save interval15 s, 30 s, 1 min, 5 min, 15 min, 60 min
History capacity (4 MB memory)min. 7 weeks, max. 20 years
Housing and mountingCompact plastic housing for DIN rail mounting
105 × 22 × 75 mm (length × width × height)
Degree of protectionIP20
Weightapprox. 200 g
Ambient temperatureStorage: -40 to +70 °C
Operating temperature with spacing between devices: 0 to +60 °C
Operating temperature when installed side by side without spacing: 0 to +50 °C
Permissible relative humidity0 to 95 per cent RH, non-condensing
Contents of the delivery1x web-based thermo-hygrobarometer
1x W&T sensor, 2 m (temperature, relative humidity and barometric pressure)
1× quick start guide

Accessories3